7.3.18

SERVICE DISPLAY SETUP

When the device is fi rst used, the function for the service interval is deactivated.
This function can be activated with the "R3" push button (19). The maintenance interval
limit can be set within a range of 0 to 999 hours.
Setting and saving the maintenance interval limit in hours
26
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
μA
R3
20
19
5
Review counter status since last service carried out on gun
22
26
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
μA
R3
18
17
6
5
ORDER NUMBER DOC 2366600
27
Procedure
1. Press the "Service" button (25) to access
the service menu. LED (26) lights up.
2. Actuate the push button R3 (19) for a
short time, the LED (20) display lights up.
POWER
POWER
0
1
3. Use the control dial (2) to set the
maintenance interval limit you want
(e.g., 90 hours).
AquaCoat
4. Check setting in the LED display (27).
B_03383
5. The value is saved by pressing down
2
the "Spray current" push button (5)
until the LED display (27) starts to fl ash.
27
Procedure
1. Press the "Service" button (25) to access
the service menu. LED (26) lights up.
2. Actuate the push button R2 (17) for a
short time; the LED (18) display lights
POWER
POWER
0
1
up.
3. Read off display in the LED display (27).
In the example, 46 hours have passed
AquaCoat
since realization of the last spray gun
service. The bar display on the left (22)
B_03384
2
indicates that 50% of the set interval
time has passed.
4. By keeping push button (5) pressed
down, the display in the LED display (27)
can be set to "0" (reset after expiry of
the set interval limit).