Changing From Aircoat Round Jet To Aircoat Flat Jet - WAGNER AquaCoat 5010 Translation Of The Original Operating Manual

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
7.3.7

CHANGING FROM AIRCOAT ROUND JET TO AIRCOAT FLAT JET

1. Thoroughly fl ush the spray gun (1) with fl ushing agent
2. Relieve pressure
Chapter 7.3.4.
3. Secure the spray gun (1) using the trigger lock.
Changing from round jet to fl at jet
4. Unscrew round jet nozzle cap (2) incl. nozzle insert (3).
5. Unscrew nozzle insert (3) using nozzle spanner (4).
6. Unscrew nozzle nut (5). Remove nozzle screw joint (7) and sealing fi tting (8) from the
nozzle body (6). Thoroughly clean all parts.
7. Insert desired ACF5000 nozzle (11) into the valve housing.
8. Put the air cap (10) on the nozzle (11) and pay attention to the position of the guide
surfaces.
9. Screw union nut with attached nozzle guard (9) to the gun body and make sure that
the air cap horns lie in the designated recess (Y).
10. Before tightening with the air cap horns (Y), set the desired jet level and then tighten
the union nut to stop by hand.
Changing from fl at jet to round jet
4. Unscrew union nut (9) with air cap (10) and ACF5000 nozzle (11).
5. Remove air cap (10).
6. Press ACF5000 nozzle (11) out of air cap (10) by hand. Thoroughly clean all parts.
7. Insert nozzle screw connection (7) and sealing fi tting (8) into nozzle body (6).
8. Screw nozzle nut (5) onto nozzle body (6).
Do not screw on nozzle nut completely. There must be play for the atomizing air
between the nozzle nut and the nozzle body.
9. Screw on nozzle insert (3) using nozzle spanner (4).
10. Screw round jet nozzle cap (2) with nozzle insert (3) onto spray gun and tighten by hand.