WAGNER AquaCoat 5010 Translation Of The Original Operating Manual page 116

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
Activities
6. Check door switch
- Open the cabinet door.
- Switch on the control unit.
- Switch air on.
- Actuate the trigger on the spray gun.
Electrical door switch test:
- The high voltage must remain switched off .
- The control unit displays error E30.
Pneumatic door switch test:
- The grounding switch must remain closed (below).
7. Test grounding switch
- Close cabinet door.
- Air tap closed.
- Remove gun
The "High-voltage" LED illuminates.
- Voltage indicator 0 kV.
- Current 80-100 μA.
8. Test door lock
- Main switch off .
- Air on.
- Main switch on
- Main switch off
9. Test spraying
- Close cabinet door.
- Main switch on.
- Set high voltage to 5 kV.
- Remove gun.
- With the gun removed, gradually increase the high voltage up to maximum
voltage (70 kV).
The spray current must not exceed 50 μA.
- Main switch off .
ORDER NUMBER DOC 2366600
Door locked.
Door unlocked.
Aid tools
116

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquacoat 5020

Table of Contents