Commissioning; Safety Instructions; Preparation - WAGNER AquaCoat 5010 Translation Of The Original Operating Manual

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
6.9

COMMISSIONING

6.9.1

SAFETY INSTRUCTIONS

Observe the safety instructions in Chapter 4, Chapter 7.2 and Chapter 8.1.2.
Only metal tanks may be used for product and fl ushing agents, no plastic tanks.
6.9.2

PREPARATION

Before every start-up, the following points should be observed as laid down in the
operating manual:
- Secure gun with safety clip.
- For underframe with rolls (option): Lock all four swivel rollers with the footbrake.
- Check the permissible pressures.
- Check all connections for leaks.
- Check hoses for damage in accordance with Chapter 8.2.9.
Connect the compressed air
Connect the AquaCoat system to the compressed air source (8).
Fill the devices with fl ushing agent
The devices are tested during manufacturing with emulsifying oil, pure oil or solvent.
Possible residues must be fl ushed out of the circuits with a solvent (fl ushing agent) before
commissioning.
- Puma and EvoMotion: Fill separating agent in accordance with pump's operating manual.
- Fill the empty device with fl ushing agent in accordance with pump's operating manual.
Impurities in the spraying system!
Spray gun blockage.
Flush the spray gun and paint supply with a suitable fl ushing agent before
commissioning.