Protective And Monitoring Equipment - WAGNER AquaCoat 5010 Translation Of The Original Operating Manual

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
5.3

PROTECTIVE AND MONITORING EQUIPMENT

Protective and monitoring equipment!
Risk of injury and damage to the device.
The following elements are provided for system safety:
Safety element
Grounding switch (30)
Electrical door switch (17)
Pneumatic door switch (18)
Leakage resistance (32)
Door lock
Grounding band (16) in the
cabinet door.
Trigger lock
Anti-contact guard for fl at jet
nozzle
Door lock
Only open or close the cabinet door (2) when the
control unit (3) is switched off .
One second after the control unit (3) has been
switched off , the system is grounded and the door
lock opened.
ORDER NUMBER DOC 2366600
WARNING
Protective and monitoring equipment must not be removed,
modifi ed or rendered unusable.
Regularly check for perfect functioning.
If defects are detected on protective and monitoring equipment,
the system must not be operated until these defects are remedied.
Function
Grounding the potential equalization lines and pump
support (for Puma / EvoMotion) or the stripped part
of the product hose (for Cobra).
The grounding switch is closed with an open cabinet
door (potential equalization lines are grounded).
Reduces the high voltage in a controlled manner.
Cabinet door can not be opened when the control
unit is switched on.
The grounding band is grounded over the pneumatic
door switch with a closed cabinet door.
Locks the trigger of the spray gun.
Helps prevent accidental touching of the nozzle.
Power
1
0
1 s
B_05871