WAGNER AquaCoat 5010 Translation Of The Original Operating Manual page 90

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
Pin no. Designation
2 in
Fault reset
3 out
Fault output
4 in *
DC kV in
5 in *
DC μA in
6 out
DC kV out
7 out
DC μA out
* If the external set value specifi cation function will be used, parameter C12 must be set to "on" at the
VM 5020W control unit (see Chapter 7.4.1).
Analog output
The analog outputs are not power outputs, but merely signal outputs.
ORDER NUMBER DOC 2366600
Description
Potential-free contact (button) between pin 2 and pin 8 (ground)
- If there is a fault, it can be acknowledged by pressing a button.
- Acknowledgement is only given via the negative edge.
If there is a fault, +24 V DC is issued at pin 3 in reference to pin 8 (ground).
Maximum current 0.5 A
Set value specifi cation for high voltage. *
Analog d.c. voltage input at pin 4 in reference to pin 8 (ground).
0.1 V corresponds to 1 kV
7.0 V is a maximum specifi cation and corresponds to 70 kV
Set value specifi cation for spray current limitation *
Analog d.c. voltage input at pin 5 in reference to pin 8 (ground)
0.1 V corresponds to 1 μA
10.0 V is a maximum specifi cation and corresponds to 100 μA
Output of current actual voltage.
Analog d.c. voltage output at pin 6 in reference to pin 8 (ground).
0.1 V corresponds to 1 kV
7.0 V is a maximum specifi cation and corresponds to 70 kV
Output of current actual spraying current.
Analog d.c. voltage output at pin 7 in reference to pin 8 (ground).
0.1 V corresponds to 1 μA
10.0 V is a maximum specifi cation and corresponds to 100 μA
90