Disassembling Vm 5020W Control Unit; Opening The Control Unit - WAGNER AquaCoat 5010 Translation Of The Original Operating Manual

Aircoat spraying system for non-fl ammable liquids
Table of Contents

Advertisement

EDITION 02/2016
OPERATING MANUAL
10.5

DISASSEMBLING VM 5020W CONTROL UNIT

1. Switch off control unit and open cabinet door (1).
2. Lock the compressed air supply and decompress the system.
3. Loosen and unscrew screw (2).
4. Carefully remove control unit (3) forwards. Pay attention to connecting lines and
connecting cables at the back of the control unit!
1
10.6

OPENING THE CONTROL UNIT

1. Dismount the control unit from the
AquaCoat system (see Chapter 10.5).
2. Place control unit on a suitable surface.
3. Loosen and unscrew screw (1).
4. Remove cover (2) from housing.
5. When the repair is complete, replace the
cover (2) on the housing and fasten with
the screws (1).
Attention: Connect the grounding
cable to the cover.
ORDER NUMBER DOC 2366600
2
1
2
3
2
B_05899
B_03533