Universal Robots UR5 Service Manual page 202

Hide thumbs Also See for UR5:
Table of Contents

Advertisement

C499A2
Actual position has
a an error and isn't
final. Position error
C499A3
Target position
C499A4
Actual average
position
C499A5
Actual position
variance
C499A6
Actual position min
to max delta
C499A7
Actual sample
position number
C720A2
LVD (low voltage
detection)
C710A
ROM Test
C710A0
Critical error
C710A1
ROM corrupted
C710A2
Failed to validate
CRC on invariant
data in RAM
C710A3
Unexpected size of
invariant data
C710A4
Failed to validate
CRC on code
segment in RAM
C720A
Low Voltage
Detection (LVD)
UR5
Motor encoder calibration
status
Motor encoder calibration
status
Motor encoder calibration
status
Motor encoder calibration
status
Motor encoder calibration
status
Motor encoder calibration
status
Low Voltage warning level
reached
A critical error occurred
during ROM validation
A critical error occurred
during ROM validation
A critical error occurred
during ROM validation
A critical error occurred
during ROM validation
A critical error occurred
during ROM validation
196
7. Troubleshooting
Same as C499A
Same as C499A
Same as C499A
Same as C499A
Same as C499A
Same as C499A
Same as C720A
 a) Do a complete rebooting
sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance
Same as C710A
Same as C710A
Same as C710A
Same as C710A
Same as C710A
a) Do a Complete rebooting
sequence
b) Check for loose
connections
d) Update software
e) Contact your local
Universal Robots service
provider for assistance
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

20143500012016351863201635186420193516252019351626