7. Troubleshooting
C53A2
IO Overcurrent
detected. Max is
600mA
C55A
Safety system error
C55A23
Safety relay error
(minus connection)
C55A24
Safety relay error
(plus connection)
C55A33
Safety relay error (a
relay is stuck)
C55A34
Safety relay error
(relays are not on)
C55A50
Voltage present at
unpowered robot
Service Manual
Safety system malfunction
Current distributor error
Current distributor error
Current distributor error
Current distributor error
Safety Control Bord
hardware fault
107
a) Check Motherboard,
Control Board, Screenboard,
Current distributor (Euromap,
if installed).
b) Check safety devices and
cables/connections to these
devices.
c) Do a Complete rebooting
sequence
a) Check cable from Control
Board to Current distributor
or 48V Power supply and
Current distributor for issues
b) Do a Complete rebooting
sequence
a) Check cable from Control
Board to Current distributor
or 48V Power supply and
Current distributor for issues
b) Do a Complete rebooting
sequence
a) Check cable from Control
Board to Current distributor
or 48V Power supply and
Current distributor for issues
b) Do a Complete rebooting
sequence
a) Check cable from Control
Board to Current distributor
or 48V Power supply and
Current distributor for issues
b) Do a Complete rebooting
sequence
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Control Board