C74A32
Signal lost
=Misaligned
readhead or
damaged ring
C74A64
Signal low =Too far
from magnetic ring
C74A128
Signal saturation
=Too close to
magnetic ring
C75A
Joint encoder error
C75A1
Invalid decode:
Readhead
misalignment, ring
damaged or external
magnetic field
present.
C75A2
Speed reading is not
valid
C75A4
System
error=malfunction or
inconsistent
calibration detected
C75A8
Supply voltage is out
of range
C75A16
Temperature is out
of range
C75A32
Signal lost
=Misaligned
readhead or
damaged ring
Service Manual
Magnetic encoder error
(absolute encoder).
Argument = sum of C75
errors
113
 Check encoder connections
a) Do a Complete rebooting
sequence.
b) Check grounding and
shielding for EMC problems.
c) If this happens more than
two times in a row, replace
joint
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
joint
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
joint
a) Do a Complete rebooting
sequence.
b) Check grounding and
shielding for EMC problems.
c) If this happens more than
two times in a row, replace
joint