C283A3
Power not removed
from the motors
while in Emergency
Stop
C283A4
Failed to power on
the Robot arm
C283A5
Invalid pin-
configuration
received
C283A6
Trying to reassign
pin configuration
with specified
configuration
C283A7
Joint exceeded the
velocity limit
C283A8
The System
Emergency Stop
Output is not active
C283A9
System Emergency
Stop Output
disagreement within
the safety system
C283A10
Robot Emergency
Stop Input
disagreement within
the safety system
C283A11
System Emergency
Stop Input
disagreement within
the safety system
C283A12
Safeguard Stop Input
disagreement within
the safety system
UR5
Failed to activate the
System Emergency Stop
Output. The output is active
when voltage is low
The input signals are not
switching simultaneously or
are incorrectly connected.
The input signals are not
switching simultaneously or
are incorrectly connected.
The input signals are not
switching simultaneously or
are incorrectly connected.
The input signals are not
switching simultaneously or
are incorrectly connected.
160
7. Troubleshooting
a) Make sure output is not
short circuited to a power
supply
a) Ensure both inputs are
properly connected
b) Contact your local
Universal Robots service
provider for assistance.
a) Ensure both inputs are
properly connected
b) Contact your local
Universal Robots service
provider for assistance.
a) Ensure both inputs are
properly connected
b) Contact your local
Universal Robots service
provider for assistance.
a) Ensure both inputs are
properly connected
b) Contact your local
Universal Robots service
provider for assistance.