7. Troubleshooting
C71A2
Hardware is size2,
wrong firmware at
the joint
C71A3
Hardware is size3,
wrong firmware at
the joint
C71A4
Hardware is size4,
wrong firmware at
the joint
C71A5
Invalid hardware
revision
C71A6
ADC calibration
failed
C71A7
Unknown error result The motor wires are
C71A8
Motor short circuit
to ground or H-bridge
problems
C71A9
Motor indication
signal does not work
C71A10
Phase 1 is
unconnected or not
working
C71A11
Phase 2 is
unconnected or not
working
C71A12
Phase 3 or multiple
phases is
unconnected or not
working
C71A50
Current sensor test
failed
Service Manual
damaged, bad connection in
screw terminals or defect
PCB
The motor wires are
damaged, bad connection in
screw terminals or defect
PCB
The motor wires are
damaged, bad connection in
screw terminals or defect
PCB
The motor wires are
damaged, bad connection in
screw terminals or defect
PCB
The motor wires are
damaged, bad connection in
screw terminals or defect
PCB
The wire is (1) damaged or
(2) has been disconnected
from the PCB (not likely) or
(3) defect PCB
Sensor reported wrong
current when probed
111
Update firmware
Update firmware
Update firmware
a) Check joint for damaged or
loose connections.
b) Replace the joint
a) Check joint for damaged or
loose connections.
b) Replace the joint
a) Check joint for damaged or
loose connections.
b) Replace the joint
a) Check joint for damaged or
loose connections.
b) Replace the joint
a) Check joint for damaged or
loose connections.
b) Replace the joint
a) Check joint for damaged or
loose connections.
b) Replace the joint
a) Check joint for damaged or
loose connections.
b) Replace the joint