C200A
Safety Control Board
hardware error
C200A1
Hardware ID is
wrong
C200A2
MCU type is wrong
C200A3
Part ID is wrong
C200A4
RAM test failed
C200A5
Register test failed
C200A6
pRom Crc test failed
C200A7
Watchdog reset the
processor
C200A8
OVG signal test not
passed
UR5
Safety Control Board: uP-A
has detected an error:
Wrong Safety Control Board
Safety Control Board: uP-A
has detected an error
Safety Control Board: uP-A
has detected an error
Safety Control Board: uP-A
has detected an error
Safety Control Board: uP-A
has detected an error
Safety Control Board: uP-A
has detected an error:
firmware error
Safety Control Board: uP-A
has detected an error
Safety Control Board: uP-A
has detected an error: over
voltage generator
134
7. Troubleshooting
 Check Safety Control Board
functionality
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board