C192A20
SPI output error
detected
C192A21
Momentum
disagreement
C192A22
Robot moving output
disagreement
C192A23
Wrong processor ID
C192A24
Wrong processor
revision
C192A25
Potential brownout
detected
C192A26
Emergency stop
output disagreement
C192A27
Safeguard stop
output disagreement
C192A28
Robot not stopping
output disagreement
C192A29
Safeguard reset
input disagreement
C192A30
Safety processor
booted up in fault
mode
C192A31
Reduced Mode
Output disagreement
C192A32
Not Reduced Mode
Output disagreement
C192A33
A timing issue
occurred during
startup. Please
restart to proceed
UR5
Power supply for the I/O is
not detected
Voltage drop on Control
Board or defect Safety
Control Board
Checksum disagreement
between safety processors
uA and uB
130
7. Troubleshooting
Check if the connection to
the internal power supply is
correct. If an external power
supply is being used, check if
it is powered on and at the
correct voltage.
Check safety devices and
cables/connections to these
devices
Check safety devices and
cables/connections to these
devices
Check safety devices and
cables/connections to these
devices
Check safety devices and
cables/connections to these
devices
Check safety devices and
cables/connections to these
devices
Check safety devices and
cables/connections to these
devices
Check safety devices and
cables/connections to these
devices