Universal Robots UR5 Service Manual page 194

Hide thumbs Also See for UR5:
Table of Contents

Advertisement

C309A10
Lost more than
allowed Keep-Alive
System messages in
a row from Safety
Control Board-uPA
C309A11
Lost more than
allowed Keep-Alive
System messages in
a row from Safety
Control Board-uPB
C309A12
Keep-Alive System
C309A13
Keep-Alive System
C309A14
Keep-Alive System
C309A15
Keep-Alive System
C311A0
Delay Callback
C312A
Data validation
C312A0
Critical error
C312A1
Data validation
C312A2
Data validation
C312A3
Data validation
C312A4
Data validation
C312A5
Data validation
UR5
An invalid amount of Keep-
Alive System messages
have been lost from the
Safety Control Board
Processor A
An invalid amount of Keep-
Alive messages have been
lost from the Safety Control
Board Processor B
Go-to-Violation command
received in Keep-Alive
System message from SCB-
uPA.
Go-to-Violation command
received in Keep-Alive
System message from SCB-
uPB.
Invalid command received
in Keep-Alive System
message from SCB-uPA.
Invalid command received
in Keep-Alive System
message from SCB-uPB.
The timer is not available
A critical error occurred
during data validation
Missed several packages
Unexpected sequence
Several failures in a row
Received a package at an
unexpected time
Package had unexpected
type
188
7. Troubleshooting
a) Conduct a complete
rebooting sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance
a) Conduct a complete
rebooting sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance
a) Do a Complete rebooting
sequence
b) Check for ESD noise.
c) Update software
d) Contact your local
Universal Robots service
provider for assistance.
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading