C39A101
Watchpoint fault:
Motor-Control task
timeout
C39A102
Watchpoint fault:
Motor-encoder task
timeout
C39A103
Watchpoint fault:
Joint-encoder task
timeout
C39A104
Watchpoint fault:
Communication task
timeout
C39A105
Watchpoint fault:
RAM-test task
timeout
C39A106
Watchpoint fault:
CalVal-test task
timeout
C39A107
Watchpoint fault:
ROM-test task
timeout
C40A
AD-Converter hit
high limit joint
C41A
RC Oscillator Trim
register hit high limit
C42A
RC Oscillator Trim
register hit low limit
C43A
Change in invariant
memory detected
C43A1
Current sensor gain
C44A
CRC check failure on
primary bus
C44A0
Base
C44A1
Shoulder
UR5
EMC issue external or
electronics internal
Serial communication
problem with joint or
secondary bus node
102
7. Troubleshooting
 Same as C39A1
 Same as C39A1
 Same as C39A1
 Same as C39A1
 Same as C39A1
 Same as C39A1
 Same as C39A1
Check grounding and
shielding for EMC problems
a) Check black 2-wire
connectors and wires in
joints.
b) Do a Complete rebooting
sequence.
c) If this happens more than
two times in a row, contact
your local service provider for
assistance.