C328A1
Transceiver
miscellaneous
C328A2
Flash device is not
supported, check
JEDEC data for
device
C329A1
AXI STREAM
C329A2
AXI STREAM
C330A
Injection Molding
Machine Interface
IMMI IO
C330A1
Injection-Molding-
Machine-Interface E-
Stop output
readback does not
match the produced
value
C330A2
Injection-Molding-
Machine-Interface
Moulding Area Free
output readback
does not match the
produced value
C330A3
Injection-Molding-
Machine-Interface
24V IO voltage
outside acceptable
range
C330A4
Injection-Molding-
Machine-Interface
48V voltages outside
acceptable range
UR5
Timeout while waiting for
the SoC, the SoC was lost
or delayed more than
expected
The flash device's JEDEC ID
does not match a supported
flash device
FiFo overflow on interface
FiFo overflow cleared
First byte: produced value,
second byte: read value
First byte: produced value,
second byte: read value
The voltage measured on
the 24V IO rail is lower than
expected
The voltages measured on
the 48V rails are lower than
expected
192
7. Troubleshooting
a) Conduct a complete
rebooting sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance
Check E-stop output
Check output
a) Check the fuses on the
Injection-Molding-Machine-
Interface
b) Verify there are no short
circuits on the 24V IO
connectors
c) Contact your local
Universal Robots service
provider for assistance
a) Check the fuses on the
Injection-Molding-Machine-
Interface
b) Verify there are no short
circuits on the IO connectors
c) Contact your local
Universal Robots service
provider for assistance
Service Manual