7. Troubleshooting
C4A94
Packet counter
disagreement in
packet from
processor A to B
C4A95
Packet counter
disagreement in
packet from
processor A to
Teach Pendant and
EUROMAP
C4A100
Communication lost
due to Packet
counter
disagreements
C5A
Heavy processor
load warning
C10A
Controller
communication
issue
C10A1
Lost packet from
Controller
C10A101
Controller packet
received too early
C10A102
Packet counter does
not match
C10A103
Controller is sending
packets too often
C11A
Bad CRC
C12A
Unknown message
error
C14A1
Debug message
C14A2
Debug message
C14A3
Debug message
C17A
Communication
error between Safety
Control Board and
Motherboard
Service Manual
 More than 1 package lost
 More than 1 package lost
 More than 1 package lost
 Too much instructions
being sent at the same time
Serial communication
problem with joint
99
Same as C4A12
Same as C4A12
Same as C4A12
 Review communication
frequency between robot and
external equipment
Check black 2-wire
connectors and wires in
joints
a) Check Ethernet connection
between circuit boards
b) Do a Complete rebooting
sequence
c) Update the software