Universal Robots UR5 Service Manual page 109

Hide thumbs Also See for UR5:
Table of Contents

Advertisement

7. Troubleshooting
C44A2
Elbow
C44A3
Wrist 1
C44A4
Wrist 2
C44A5
Wrist 3
C44A6
Tool
C44A80
CRC Check failure
on primary bus.
C45A
AD-Converter error
C46A
Loose gearbox or
bad encoder
mounting
C47A
AD-Converter hit low
limit
C49A
RS485 receive
warning
C49A200
Secondary RS485
bus is down
C50A
Robot powerup issue Electrical error control box
C50A1
Voltage detected at
24V rail before
startup
C50A2
Voltage present at
unpowered robot
C50A5
Powersupply voltage
too low
C50A6
Powersupply voltage
too high
C50A11
Voltage not detected
at 24V rail after
startup
C50A15
Warning, waiting for
SafetySYS2
Service Manual
Interference on the
communication field bus.
Mechanical problem in gear
related to encoder mounting
EMC issue external or
electronics internal
Bus for: Teach Pendant,
Processor A and Processor
B on Control Board
103
a) Do a Complete rebooting
sequence
b) If this happens more than
two times in a row, replace
joint
Check grounding and
shielding for EMC problems
Check TCP/IP-12V cable to
Teach Pendant
Remove all external
connections to I/O-interface
of Safety Control Board.
Check for short circuit
Check 48 V cable between
power supply and Control
Board
UR5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

20143500012016351863201635186420193516252019351626

Table of Contents