Universal Robots UR5 Service Manual page 115

Hide thumbs Also See for UR5:
Table of Contents

Advertisement

7. Troubleshooting
C55A120
Robot current is too
high while
emergency stopped
C55A121
Robot current is too
high while safeguard
stopped
C56A
Overvoltage
shutdown
C57A
Brake release failure
C57A1
Joint did not move or
motor encoder is not
functioning
C57A2
Large movement
detected during
brake release
C57A3
Robot was not able
to brake release, see
log for details
C58A
Motor encoder not
calibrated
C59A
Overcurrent
shutdown
C60A
Energy surplus
shutdown
C61A
Idle power
consumption to high
Service Manual
Voltage exceeded 55V
Overcurrent in joint.
Argument = Current in
Amps
The power supply is
sending energy to the
energy eater
The system is drawing
more power than expected
while idle
109
a) Check Energy Eaters cable
and connections.
b) Check Energy.
c) Replace Energy Eater
a) Check Brake, solenoid.
b) Check TCP configuration,
payload and mounting
settings
a) Check for short circuit.
b) Do a Complete rebooting
sequence.
c) If this happens more than
two times in a row, replace
joint
a) Ensure power grid is not
delivering more than 48V
b) Measure robot energy
input
c) Contact your local
Universal Robots service
provider for assistance.
a) Check Energy Eaters
cables and connections
b) Check Energy Eater
c) Replace Energy Eater
UR5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

20143500012016351863201635186420193516252019351626