4.2
Copy (Duplicate Cutting)
The function to cut specified numbers of cutting data stored in the buffer memory is called COPY.
Supplement
Do not send new data to plotter while copying. Cutting data in the buffer memory will be cleared.
Previous cutting data will be cleared and newly sent data will be stored as cutting data if you send new data with 10 seconds or
more interval from the time it finished cutting.
It can not copy if data is more than 1.6 MB because it cannot be stored in the buffer memory of the plotter.
Buffer memory that can be used for copy will decrease if you turn on the data sort. Turn off the data sort when you need to copy
cutting with large data. See "Sorting the Cutting Data"
Watch out that it does not fall out of media when cutting with copy function.
If the original cutting data to be copied starts away from the origin point, copied cutting will also start away from the origin point. To
avoid wasted space, create the cutting data close to the origin point.
Alignment registration mark data cannot be copied.
When Media Change mode is off
Copy is performed in following order.
Second copy
Origin point
First cut
Copy origin
point
It will copy in following order when COORDINATE AXES ROTATION is set.
Copy origin point
First cut
Origin point
Fourth copy
Fourth copy
Copy
space
Copy
space
Third
copy
First copy
Second copy
Third copy
First copy
Copy
space
Copy
space
Fifth copy
for data sort.
P.7-2
4-11