CLEAR B. WEAR VALUE (estimated distance method)

Make certain to always clear the estimated distance (return to 0) when changing cutter blades. The new
estimated distance will then be recalculated to the new blade.
Operation
1
Press the [PAUSE/MENU] key.
MENU screen is displayed.
2
Press [1] key (TOOL).
TOOL SETTING screen (1/3) is displayed.
3
Press [2] key (BLADE WEAR SETUP).
BLADE WEAR SETUP screen is displayed.
4
Press [4] key (CLEAR B. WEAR VALUE).
CLEAR B. WEAR VALUE screen is displayed.
5
Press the POSITION (
6
Confirm the group you want to clear and press [ENTER] key
(SET).
Clear confirmation screen is displayed.
) keys to select the group.
6-20
Supplement
Perform the settings in Normal menu.
Supplement
It will return to BLADE WEAR SETUP screen
without changing the settings when you press
the POSITION ( ) key (CANCEL).