A540-55-880 Issue D
Wait for at least four minutes after switching off the electrical supply before touching any electrical
component on the dry pumping system.
Route and secure cables, hoses and pipelines during maintenance to avoid possible risk of trips or
entrapment.
Ensure that any oil or water collected in the secondary containment drip tray is removed before moving the
system.
The enclosure panels should only be removed with the use of a special tool, when the pump system has been
stopped and allowed to cool sufficiently (as an indication the system should be left for one hour with cooling
water still connected with flow characteristics as defined in
Wear the appropriate safety clothing when coming into contact with contaminated components. Dismantle
and clean contaminated components inside a fume cupboard.
O-ring replacement intervals vary depending on the application.
Dispose of components, grease and oil safely.
Take care to protect sealing faces from damage.
Do not touch or inhale the thermal breakdown products of fluorinated materials which may be present if the
system has been overheated to 260 °C and above. These breakdown products are very dangerous.
Fluorinated materials in the system may include oils, greases and seals. The system may have overheated if
it was misused, if it malfunctioned or if it was in a fire. Edwards Material Safety Data Sheets for fluorinated
materials used in the pump are available on request.
The system requires little user maintenance. Pump protection sensors fitted to the system do not require routine
maintenance. The maintenance operations that can be carried out by the customer are described in the following
sections; other maintenance must be carried out by Edwards service centres (refer to
maintenance operations depends on the process. Adjust the frequency of maintenance operations according to
customer experience.
When maintaining the system, use replacement parts, seals and fittings supplied by Edwards, refer to
Ensure that nitrogen and cooling water supplies are connected in parallel and that they meet the specifications given
in
Section
2. Contact Edwards for more information.
5.2

Relocate the system for maintenance

The substances that accumulate in the exhaust pipe, elbow and check valve can be dangerous. Do
not allow these substances to come into contact with skin or eyes. Do not inhale vapours from
these substances. Fit blanking caps to the inlet and outlet flanges when moving the exhaust pipe,
elbow or check valve around the workplace.
The majority of synthetic oils/grease can cause inflammation of the skin (dermatitis). Safety
precautions must be taken to prevent prolonged skin contact with these substances. Use of
suitable protective gloves and clothing along with a respirator is recommended if contact with the
substance is anticipated. System process gases and residue can be highly toxic. Take all necessary
precautions when handling components that have, or could have, come into contact with them,
including O-rings, lubricants and all exhaust accessories.
Use suitable lifting equipment to move the system. Failure to do so can cause injury to people and
damage to the equipment.
Page 38
Section
WARNING
WARNING
© Edwards Limited 2015. All rights reserved.