Programming Output Voltage; Figure 3.5 Programming Output Voltage With A 0-5Vdc Source - Xantrex XKW 8-350 Operating Manual

Xkw 3000 watt series programmable dc power supply
Table of Contents

Advertisement

Programming
Programming Output Voltage with a 0-5Vdc Source
Output
1. Remove the jumpers connecting pins 8 to 9 and 20 to 21 on connector J3.
Voltage
2. Connect the external programming source between pins 9 (voltage
Varying the programming voltage from 0 to 5Vdc will cause the output to vary from
0 to 100% of the model rating. The output current limit may be programmed using
another source or set locally by adjusting the front panel current limit control.

Figure 3.5 Programming Output Voltage with a 0-5Vdc Source

Programming Output Voltage with a 0-10V Source
1. Set internal jumper JMP1 to its A-B location.
2. Remove the jumpers connecting pins 8 to 9 and 20 to 21 on connector J3.
3. Connect the external voltage programming source between pins 9 (voltage
Varying the programming voltage from 0 to 10Vdc will cause the output voltage to
vary from 0 to 100% of the model rating. The output current limit may be
programmed using another source or set locally by adjusting the front panel current
control.
Note:
Resetting internal jumpers may require a recalibration of the programming circuit to
maintain programming accuracy. See
page
Revision A
programming input/positive) and 12 (return).
WARNING
Exercise caution when resetting internal jumpers. Follow the procedures for
removing the cover and resetting jumpers in
Programming, Sensing, and Monitoring" on page 48
programming input/positive) and 12 (return).
82.
Remote Programming of Output Voltage and Current Limit
J3
+
0 - 5 V
"Configuring for Remote
"Calibrating for Programming Accuracy" on
Operation
.
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents