Error Codes; Table 3-9 Error Codes - Xantrex ENET-XFR Operating Manual

Internal ethernet and rs-232 interface for xfr series programmable dc power supplies
Table of Contents

Advertisement

Error Codes

TM-XR9B-01XN
If the ERR flag in the accumulated status or fault registers has been
activated, an ERR? query will return an error number which corresponds
to an event described in the following table. The ERR? query will also
clear the ERR bit in the register.

Table 3-9 Error Codes

E r r o r # E r r o r I d e n t i f i c a t i o n
0
No Errors
4
Unrecognized Character
Improper Number
Unrecognized String
Syntax Error
5
Number Out of Range
6
Attempt to Exceed Soft
Limits
7
Improper Soft Limit
8
Data Requested without a
Query Being Sent
9
OVP Set Below Output
10
Slave Processor Not
Responding
12
Illegal Calibration
E x p l a n a t i o n
Received a character such as @,*,$.
Received a numeric character but the
characters were not a proper number.
Example: VSET,±10.3
Received an invalid command.
Received an incorrectly placed word,
number, separator, or terminator.
Example: OFF SRQ, VOUT 6, MASK,
ERR
Specified a value for the command which
was outside of the allowed range.
Attempted to program a voltage or
current greater than the soft limit.
Example: VMAX 500; VSET 550 LF
Attempted to program a soft limit less
than the output value.
The controller requested data from the
power supply without first sending a
query command.
Sent an OVSET command with a trip
value lower than the output voltage.
The interface PCB slave processor did
not respond.
Attempted calibration when the supply
was not in calibration mode. See
CMODE command.
Error Codes
3–19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enet-xfr3

Table of Contents