Operation

Remote Monitoring and Status Indicators

Remote Monitoring and Status Indicators
Readback signals for remote monitoring of the output voltage and current are
available at connector J3 on the rear of the unit. A 0-5V (uncalibrated) signal
between pins 19 (positive) and 12 (negative) represents 0-100% of the rated output
voltage. A 0-5V (calibrated) signal between pins 7 (positive) and 12 (negative)
represents 0-100% of the rated output current. The offset and gain of the current
readback signal may be adjusted through holes in the cover of the unit. See
"Calibration"
Status indicators for thermal shutdown, OVP operation, remote programming and
operating mode are also available through the J3 connector.
Indicators,"
the approximate magnitude of the signal (measured with respect to pin 6 of
connector J3) and the source impedance through which the signal is fed.
Table 3.2 Status Indicators
Indicator Signal
Thermal Shutdown
OVP Circuit Activated
Remote Programming
Voltage Mode Operation
Current Mode Operation
Note: To obtain a 0-10V readback signal, you must use an external instrumentation
amplifier with the 0-5V signal.
52
for location of adjusting holes.
lists the various signals, the J3 connector pins where they are available,
J3 Pin
18
17
4
5
5
Signal Voltage
Source Impedance
+10 V
+9 V
+10 V
+10 V
- 3 V
Operating Manual for XKW 1kW Series Power Supply
Section 4,
Table 3.2, "Status
750Ω
750Ω
750Ω
750Ω
750Ω

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents