Push-In Plus Terminal Blocks
Item
Construction
Applicable wires
Applicable wire size
Wire insertion force
Screwdriver insertion
force
Wire stripping length
Ferrule length
Recommended
flat-blade screwdriver
Current capacity
Number of insertions
Recommended ferrules
*1. Without ferrules
Nomenclature of the Push-In Plus Terminal Block and Connections
 Nomenclature of the Terminal Block
<Upper side>
 Connecting Wires with Ferrules and Solid Wires
Insert the solid wire or ferrule straight into the terminal block until the end strikes the terminal block.
<Upper side>
If a wire is difficult to connect because it is too thin, use a flat-blade screwdriver in the same way as
when connecting stranded wire.
K6PM-TH Thermal Condition Monitoring Device User's Manual (H231)
Push-in compatible with 1-pole 2-terminal interwiring wiring
Hands free
Front-in front and front-release
Stranded wires, solid wires, or ferrules
2
0.25 to 1.5 mm
(AWG24 to AWG16)
8 N max. for AWG20 wire
15 N max.
*1
8 mm
, 10 mm, 12 mm
8 mm, 10 mm
XW4Z-00B (Refer to Recommended Flat-blade Screwdriver on page 2-14 under
Recommended Ferrules and Crimp Tools on page 2-14.)
10 A (per pole)
50 times
Refer to Recommended Ferrules on page 2-14 under Recommended Ferrules and
Crimp Tools on page 2-14.
Terminal (Insertion)
hole
Release hole
Terminal (Insertion) hole
Ferrules
Release hole
2 Installation and Wiring
Specification
<Lower side>
Release hole
Terminal (Insertion)
hole
<Lower side>
Release hole
Ferrules
Terminal (Insertion) hole
2
2 - 11