Omron K6PM-TH User Manual page 153

Thermal condition monitoring device
Hide thumbs Also See for K6PM-TH:
Table of Contents

Advertisement

 Actions to Take When Angle Deviation Occurs
Step
1. On the computer for
monitoring, check if
angle deviation has
occurred.
2. Identification of angle
deviation occurrence
location in the PC for
setting
3. Position adjustment
4. Resuming monitoring
K6PM-TH Thermal Condition Monitoring Device User's Manual (H231)
On the Device List of K6PM Screen, check in which Main Unit has the angle devia-
tion occurred on the PC for monitoring.
On the Monitoring K6PM Screen, check in which K6PM-TH sensor has angle devia-
tion occurred.
Move to the location of the control panel where the target sensor is present.
(Turn ON the external trigger input. The measurement is interrupted.)
Open the corresponding project file in the PC for setting
On the Setting K6PM Screen, check the sensor number in which angle deviation has
occurred.
Select the sensor number on the Setting K6PM Screen, and then click the Details
Button.
Move to the Setting sensor Screen, and perform position adjustment while referring
to the image data.
Make sure the red LED indicator is flashing.
• To cancel the angle deviation
Move to the Setting sensor screen, and
adjust the position while viewing the
image data.
Make sure the red LED stops blinking.
Return to the Setting K6PM Screen, and click the Start monitoring Button. The Main
Unit switches to the monitoring mode.
Turn OFF the external trigger input. The measurement is resumed.
7 Troubleshooting
Procedures
• Registering a new position or changing
a position
On the Setting sensor Screen, click the
Position registration Button. Press the
reset switch for the K6PM-TH sensor
angle deviation on the side surface of the
infrared thermal sensor.
7
7 - 5