Appendices
 Measured Value Display
Measurement level
Temperature of each seg-
ment and sensor internal
temperature
Differential temperature per
segment from the K6PM-TH
sensor internal temperature
Temperature of each infra-
red thermal sensor
Temperature of each pixel
Alarms of each Main Unit
(Alarms of all infrared ther-
mal sensors connected to
the Main Unit)
A-1-2

Infrared Thermal Sensor

Infrared Thermal Sensor Ratings
Item
Power
Power supply voltage
supply
Allowable operating voltage range
Power supply frequency range
Power consumption
Ambient operating temperature
Storage temperature
Ambient operating humidity
Storage humidity
Exterior color
Case material
Altitude
Applicable wires
Applicable wire size
Current capacity
Weight
Mounting
Dimensions
A - 6
Methods for checking
Main Unit (display)
The segment display of
Can be checked on the
each sensor can be
Monitoring sensor screen.
switched on the Main
Unit front-panel.
Not supported
Not supported
Not supported
The past maximum value
can be monitored on the
Monitoring K6PM
Screen.
Not supported
The temperature can be
displayed when the cur-
sor is placed on the ther-
mal image on the
Monitoring sensor
Screen.
The occurrence of an
The occurrence of an
alarm can be checked
alarm can be checked on
on the alarm bar.
the Device List of K6PM
Screen.
Model
24 VDC
85% to 110% of the power supply voltage
---
0.4 W max./Unit at 24 VDC
-10 to +55°C (with no condensation or freezing)
-20 to +65°C (with no condensation or freezing)
25% to 85% (with no condensation)
25% to 85% (with no condensation)
Black
PC UL94-V0
2,000 m max.
Stranded wires or solid wires
0.25 to 1.5 mm
8 A (per pole)
50 g max.
*2
Mounting
Screw Mounting
43 × 60 × 25.1 mm (W×H×D) Terminals not included
K6PM-TH Thermal Condition Monitoring Device User's Manual (H231)
Software tool
Communications
• EtherNet/IP tag data
link communications
• EtherNet/IP mes-
sage communica-
tions
• Modbus TCP com-
munications
Not supported
Not supported
• EtherNet/IP mes-
sage communica-
tions
• Modbus TCP com-
munications
The occurrence of an
alarm can be checked
from the Main Unit sta-
tus.
K6PM-THS3232
*1
2
(AWG24 to AWG16)