Appendices
Infrared Thermal Sensor Characteristics
Item
Temperature
measurement
Other functions
Output
Applicable
standards
Recommended fuse
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Indicators
*1. Accuracy may vary depending on the measured distance, the object's emissivity, and ambient temperature.
*2. Accuracy for the central four segments when the measured object is 25°C to 80°C. If a high temperature object
is measured with the outer 12 segments, the accuracy may decrease due to area effect.
*3. Performance of central four segments. ±2°C for the outer 12 segments.
*4. Make ON/OFF settings on the DIP switch Pin 2 (default value: OFF). For details, refer to DIP Switch Settings
on page 1-17.
*5. Since the operation is not stable at a location subject to vibrations, it may not be possible to detect angle de-
viation.
*6. During screw mounting
A - 8
Model
Temperature mea-
Temperature measurement range: 0.0°C to 200.0°C (32.0°F to 392.0°F)
surement range
Detection resolu-
32 × 32 (1,024 pixels)
tion
Temperature accu-
±5°C (at an ambient temperature of 25°C)
racy
Emissivity
0.94
Reproducibility
±1°C (at an ambient temperature of 25°C)
Temperature drift
0.15°C
Warm up time
15 minutes
Viewing angle
90° × 90°
[FOV]
Temperature mea-
Outputs K6PM-TH sensor error in following condition
surement range
Temperature: 200.0°C or higher
exceeded
Sensor internal temperature: 80°C or higher
Angle deviation
Detection of only angle deviation
*4
detection
Angle deviations of 5° (typ) min. and those that continue for 3 seconds
min. can be detected.
Communications
RS-485 communications
method
Maximum cable
500 m
length
Approved stan-
UL61010-1 (listing) installation location: Pollution degree 2
dards
Korean Radio Waves Act
Conforming stan-
RCM
dards
EMC
EN61326-1 (EMI: Class A EMS: Industrial Location), Measured tempera-
ture fluctuation range: ±6°C
T2A, time lag, shut-off capacity
20 MΩ min.
Between all terminals and the case
1,000 VAC for 1 minute
Between all terminals and the case
Frequency: 10 to 55 Hz, 0.35-mm single amplitude in X, Y, and Z direc-
tions (10 sweeps of 5 min each)
150 m/s
IP20
Power indicator
Green (when power is on: Lit, when power is not on: Not lit)
Communications
Orange (when communications are performed: Lit, when communica-
indicator
tions are not performed: Not lit)
Alarm indicator
Red (when a sensor error occurs: Lit, when an angle deviation is
detected: Flashing)
K6PM-THS3232
*5
*6
2
, 3 times each in 6 directions along 3 axes
K6PM-TH Thermal Condition Monitoring Device User's Manual (H231)
*1*2
*3
*6