Omron K6PM-TH User Manual page 125

Thermal condition monitoring device
Hide thumbs Also See for K6PM-TH:
Table of Contents

Advertisement

 Instance Attribute ID
The instance attribute ID specifies the per-instance attribute.
Attribute ID
Parameter name
01 hex
Vendor ID
02 hex
Device Type
03 hex
Product Code
04 hex
Revision
Major Revision
Minor Revision
05 hex
Status
06 hex
Serial Number
07 hex
Product Name
*1. Product code
Models
K6PM-THMD-EIP
*2. Status of the built-in Ether- Net/IP port
Bit
0
Owned
1
Reserved.
2
Configured
3
Reserved.
4 to 7
Extended Device Status
Indicates the status of the built-in EtherNet/IP port.
8
Minor Recoverable Fault
Indicates the status of the built-in EtherNet/IP port.
9
Minor Unrecoverable Fault
Indicates the status of the built-in EtherNet/IP port.
10
Major Recoverable Fault
Indicates the status of the built-in EtherNet/IP port.
11
Major Unrecoverable Fault
Indicates the status of the built-in EtherNet/IP port.
12 to 15
Reserved.
K6PM-TH Thermal Condition Monitoring Device User's Manual (H231)
5 Monitoring and Setting with the EtherNet/IP Communications
Description
Vendor ID
Device type
Product code
Device revision
Major revision
Minor revision
Status of the EtherNet/IP Port
Serial number
Product name
Product Code
512 (200 hex)
Name
Data
Attribute
Data type
Read
UINT
002F hex
Read
UINT
0304 hex
Read
UINT
*1
Read
Struct of
- - -
Read
USINT
Product specific
Read
USINT
Product specific
Read
WORD
*2
Read
UDINT
Product specific
Read
SHORT_S
Product specific
TRING
Description
Indicates when the built-in EtherNet/IP
port has an open connection as the target
of a tag data link.
Always FALSE.
Tag data link settings exist.
Always FALSE.
Indicates the status of the built-in Ether-
Net/IP port.
0: Not used
1: Not used
2: One or more I/O connection failures
3: I/O connection is not established
4: Not used
5: Serious defect occurred (MS Criticality)
6: One or more I/O connections are estab-
lished and one or more are in the RUN
state
7: One or more I/O connections are estab-
lished and all are idle
8 to 15: Unused
Always FALSE.
Always FALSE.
When the MS indicator matches condi-
tions of the flashing red: True
When the MS indicator matches condi-
tions of the flashing red: True
Always FALSE.
Default value
5
5 - 23

Advertisement

Table of Contents
loading

This manual is also suitable for:

K6pm-thmd-eipK6pm-ths3232

Table of Contents