Precautions for Safe Use
 Sensor Only
(1) To prevent wiring materials from smoking or ignition, use the wiring materials given in the following
table.
Wire type
Solid/ Stranded
wire
(2) Check that the LED indicators are operating normally. Depending on the application environment,
the indicators and other plastic parts may wear prematurely and become difficult to see. Check and
replace these parts regularly.
(3) Do not use the sensor at temperatures exceeding the maximum operating temperature. Doing so
may result in deterioration or be damaged of the internal components. Consider the effect of heat
radiated from the measurement object as well.
(4) When setting the distance from the measurement object, also consider the voltage generated by
the measurement object as well as safety standard certification requirements.
8
Wiring
Recommended Wire
material
Copper
2
0.25 to 1.5 mm
AWG24 to AWG16
K6PM-TH Thermal Condition Monitoring Device User's Manual (H231)