Operation Command - Omron K6PM-TH User Manual

Thermal condition monitoring device
Hide thumbs Also See for K6PM-TH:
Table of Contents

Advertisement

6 Monitoring and Setting with the Modbus TCP
6-3-7

Operation Command

Address
D000 hex
Software reset
D001 hex
K6PM-TH sensor registra-
tion
D002 hex
Change the K6PM-TH sen-
sor mode
D003 hex
Reflect K6PM-TH sensor
search result
D004 hex
K6PM-TH sensor location
registration
D005 hex
Max. temperature reset
*1. W: Write using Writing of multiple registers (10 hex).
*2. Reset occurs after the command ends normally.
If the mode is already a transition target, the exception code 04 hex (failure in associated device) is returned.
If 0 sensors are registered for K6PM-TH sensor type registration, the exception code 04 hex (failure in associ-
ated device) is returned.
*3. In the monitoring mode, the exception code 04 hex (failure in associated device) is returned.
*4. Register the sensor detected in K6PM-TH sensor search mode in the Main Unit.
In the monitoring mode K6PM-TH and sensor position adjustment mode, the exception code 04 hex (failure in
associated device) is returned.
*5. In the monitoring mode, the exception code 04 hex (failure in associated device) is returned.
If position registration is not performed for the target sensor, the exception code 04 hex (failure in associated
device) is returned.
6 - 18
Data name
0001 hex: Software reset
0001 hex: Cancel sensor registration. (Change
to sensor search mode)
*2
0002 hex: Register sensor. (Change to moni-
toring mode)
0000 hex: K6PM-TH sensor search mode
0001 hex: K6PM-TH sensor 1 position adjust-
*3
ment mode
0002 hex: K6PM-TH sensor 2 position adjust-
ment mode
· · ·
001F hex: K6PM-TH sensor 31 position adjust-
ment mode
0001 hex: Reflect sensor search result
*4
0001 hex: K6PM-TH sensor 1 location regis-
*5
tration
0002 hex: K6PM-TH sensor 2 location regis-
tration
· · ·
001F hex: K6PM-TH sensor 31 location regis-
tration
0001 hex: Reset the maximum temperature of
all segments of all sensors
Data Range
K6PM-TH Thermal Condition Monitoring Device User's Manual (H231)
Number
*1
R/W
of bytes
2
W
2
W
2
W
2
W
2
W
2
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

K6pm-thmd-eipK6pm-ths3232

Table of Contents