5.6.3
Operation at the Time of Error
The following table shows outputs at the time of error and actions of the outputs.
■ System alarm
Error
No
Message
STB DTB MTB LTB
10 Main CPU FAIL
Reverse
11
calculation failure
Main board
12
EEPROM failure
Main board
13
EEPROM default
Sensor board
14
failure
Sensor
15
communication
error
A/D1
16
failure[Signal]
A/D2
17
failure[Exciter]
18 Coil open
19 Coil short
20 Exciter failure
Parameter restore
27
incomplete
Indicator board
28
failure
Indicator board
29
EEPROM failure
30 LCD driver failure
Indicator board
31
mismatch
Indicator
32
communication
error
33 microSD failure
Amp EEPROM
244
Failure
SoftDL
249
Incomplete
250 SoftDL Failure
XD_ERROR
STB
20
--
--
--
Other
20
--
--
--
Other
23
--
--
--
Other
17
--
--
--
Other
20
--
--
--
Other
20
--
--
--
Other
20
--
--
--
Other
20
--
--
--
Other
17
--
--
--
Other
20
--
--
--
Other
20
--
--
--
Other
--
--
17
--
--
--
--
20
--
--
--
23
--
--
--
20
--
--
--
20
--
--
--
20
--
--
--
20
--
--
--
--
--
--
17
--
--
--
17
--
BLOCK_ERR
DTB
MTB
LTB
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Other
--
--
--
--
Other
--
--
--
Other
--
--
--
Other
--
--
--
Other
--
--
--
Other
--
--
--
Other
--
--
--
--
--
--
Other
--
--
--
Other
--
<5. Functions>
Process
Totalizer
value*
STOP
Totalizer stop Undefined
Follows
Normal
settings (see
calculation
4.2.4).
Follows
Normal
settings (see
calculation
4.2.4).
Follows
Normal
settings (see
calculation
4.2.4).
Follows
Hold Prior
settings (see
setting
4.2.4).
Follows
Hold Prior
settings (see
setting
4.2.4).
Follows
Hold Prior
settings (see
setting
4.2.4).
Follows
Hold Prior
settings (see
setting
4.2.4).
Follows
Hold Prior
settings (see
setting
4.2.4).
Follows
Hold Prior
settings (see
setting
4.2.4).
Follows
Normal
settings (see
calculation
4.2.4).
Follows
Normal
settings (see
calculation
4.2.4).
Follows
Normal
settings (see
calculation
4.2.4).
Follows
Normal
settings (see
calculation
4.2.4).
Follows
Normal
settings (see
calculation
4.2.4).
Follows
Normal
settings (see
calculation
4.2.4).
Follows
Normal
settings (see
calculation
4.2.4).
Follows
Normal
settings (see
calculation
4.2.4).
--
--
--
--
--
--
IM 01E21A02-03EN
99
Display
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm
Alarm