Idler Assembly - Toro Greensmaster eFlex 1800 Service Manual

Hide thumbs Also See for Greensmaster eFlex 1800:
Table of Contents

Advertisement

Idler Assembly

g251084
1.
Flocked bearing shield
(2 each)
2.
Flange nut
3.
Motor clamp
4.
Adaptor
Removing the Idler Assembly
Universal Groomer (Optional): Service and Repairs
5.
Socket-head screw (2 each)
6.
Clevis pin
7.
Cotter pin
8.
Collar
Note: The groomer idler assembly is located on the opposite side of the groomer
gearbox assembly.
1. Park the machine on a clean and level surface, lower the cutting units
completely to the ground, set the parking brake, and remove the key from the
key switch.
2. Remove the electric motor from the cutting unit; refer to
5–69).
3. Remove the groomer reel assembly; refer to
(page
9–12).
4. Remove the cotter pin and clevis pin from the height adjustment rod at the
front of the idler arm. Discard the cotter pin.
5. Remove the 2 socket-head screws (item 5 in
adaptor to the cutting unit, and remove the adaptor and idler assembly from
the cutting unit.
6. Inspect the shields, bearing, and bushing in the idler assembly. Remove and
discard the components that are worn or damaged.
Figure 219
10.
11.
Page 9–10
9.
Idler arm
Stub shaft
Shield
Electric Motor (page
Removing the Groomer Reel
Figure
219) that secure the
Greensmaster
®
eFlex 1800, 2100 and 2120
12189SL Rev E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster eflex 2100Greensmaster eflex 2120

Table of Contents