Fuse Block
Accessing the Fuse
Electrical System: Testing the Electrical Components
g202431
1.
Power center cover
The fuse block on the Greensmaster eFlex is attached to the machine under
the power center cover
1. Park the machine on a level surface and place the traction lever in the
N
position. Turn the key switch to the O
EUTRAL
key from the key switch.
2. Disconnect the battery pack; refer to
(page
5–7).
3. (For Models 04042, 04043, and 04046) Remove the 2 screws that secure the
rear of the power center cover to the machine
upper 2 screws on the cover, and remove the cover from the machine.
g269778
1.
Battery cover
Figure 89
eFlex 2120 Model 04046 (shown)
2.
Upper screw (2 each)
(Figure
89).
Connecting the Lithium Battery Pack
Figure 90
eFlex 2120 Model 04049 (shown)
2.
Washer head bolt (8 each)
Page 5–40
3.
Rear screw (2 each)
position and remove the
FF
(Figure
89). Then, loosen the
Greensmaster
®
eFlex 1800, 2100 and 2120
12189SL Rev E