High Voltage DC Power
The high voltage power supply (HVPS) converts +24VDC power into the high voltages required
by the xerographic subsystem.
The INTLK +24VDC power supplied via the drive PWB enters the HVPS, is routed to the trans-
formers on the board, and is modified to the voltages required for charge, developer bias,
detack, and transfer.
Refer to:
BSD 9.2 Charging and Exposure
BSD 9.3 Development
BSD 9.6 Image Transfer
The HVPS is mounted behind the drive PWB, refer to
HVPS PWB
Figure 3 HVPS PWB
Product Technical Overview
Figure
3.
Drive PWB
April 2017
IOT Modes and System Status
Refer to
Table 1
for the operating modes are available.
Table 1 Operating modes
Mode
Remaining
Running Mode
The data receiving/image creation/recording (printing) operation
mode
Ready Mode
When the system can enter the Running Mode immediately
Low Power Mode
The mode that reduces the power consumption more than the
Ready Mode
Sleep Mode*
The mode that reduces the power consumption further more
than the Low Power Mode.
Sub Power OFF Mode
The controller is maintained with the programs in running state.
The rest are in the same state as when the power is OFF.
* Applies to the International Energy Star Program.
IOT States
Refer to
Table 2
for the IOT systems are in the following states in each mode.
Running Mode
Fusing System
Maintaining
(Fusing Unit)
operating
temperature
Marking system
Operating state
(Transfer,
Developer, etc.)
Exposure System
Operating state
(LPH)
Fusing Fan
Low Speed
Rotation or High
Speed Rotation
by Temperature
Control
Marking Fan
Stop or Rotation
by Temperature
Control (Low
Speed/High
Speed
ESS (Reference) Operating state
8-6
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
Table 2 States
Low Power
Ready Mode
Mode
Sleep Mode
Maintaining
Maintaining at low
Stop state
standby
temperature
temperature
Stop state
Stop state
Stop state
Stop state
Stop state
Stop state
Temperature
Temperature
Stop state
control in Stop or
control in Stop or
Rotate (slow)
Rotate (slow)
Temperature
Temperature
Stop state
control in Stop or
control in Stop or
Rotate (slow)
Rotate (slow)
Standby
Standby
Ready to
receive
Launch Issue