Fuser Temperature Control
The heat roll temperature is monitored by the fuser non-contact sensor in the center of the heat
roll and a soft-touch thermistor at the rear end of the heat roll. Each sensor measures the tem-
perature in its region then provides temperature information to the drive PWB.
The drive PWB logic uses the inputs from the sensors to control the fusing temperature by
switching the heat rods on and off as required, refer to
The thermostats, located near the center and the front of the heat roll, provide over tempera-
ture protection. When the surface temperature of the heat roll exceeds a predetermined value,
the thermostat opens, de-energizing the fuser relay and cutting off the current to the heat rods,
refer to
BSD 10.1 Fusing Heat Control (1 of
Main heater rod
Figure 7 Fusing temperature control
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
Figure
BSD 10.1 Fusing Heat Control (1 of
2),
Figure
7.
Fuser PWB
Heat roll thermistor
Sub heater rod
Fuser NC sensor
Thermostats
Fuser Cooling
The fuser fan,
PL 40.15 Item
to
Figure 8
and
Figure
9.
7.
2).
April 2017
8-59
4, exhausts heated air from the fuser area via the ducting. Refer
Figure 8 Fuser cooling ducting
Product Technical Overview