Figure 122: Auxiliary and Console Ports
Figure 123: Routing Engine Console and Auxiliary Cable Connector
SEE ALSO
Routing Engine Interface Cable and Wire Specifications for MX Series Routers | 195
Tools and Parts Required for MX960 Router Connections | 357
Replacing Connections to MX960 Routing Engine Interface Ports | 473
Connecting DPC, MPC, MIC, or PIC Cables to the MX960 Router | 365
Connecting an MX960 Router to an External Alarm-Reporting Device | 360
Connecting an MX960 Router to an External Alarm-Reporting Device
To connect the router to external alarm-reporting devices, attach wires to the RED and YELLOW relay
contacts on the craft interface. (See
yellow alarm LED on the craft interface also activates the corresponding alarm relay contact.
The terminal blocks that plug into the alarm relay contacts are supplied with the router. They accept wire
of any gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
of wire appropriate for the external device you are connecting.
To connect an external device to an alarm relay contact (see
1. Prepare the required length of wire with gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2. While the terminal block is not plugged into the relay contact, use a 2.5-mm flat-blade screwdriver to
loosen the small screws on its side. With the small screws on its side facing left, insert wires into the
slots in the front of the block based on the wiring for the external device. Tighten the screws to secure
the wire.
Figure 124 on page
361.) A system condition that triggers the red or
2
), which is not provided. Use the gauge
Figure 124 on page
361):