Connecting Power to a DC-Powered MX960 Router with High-Capacity
Power Supplies
To install an MX960 DC high-capacity DC power supply:
1. Verify that the power switch on the power supply is in the off (O) position.
2. On the power supply, rotate the metal cover away from the input mode switch to expose the switch.
3. Move the input mode switch to position 0 for one feed or position 1 for two feeds (see
Figure 117 on page
346).
NOTE:
For a fully redundant configuration in two-feed mode, eight feeds are required.
For a non-redundant configuration, four feeds are required.
Figure 117: MX960 with High-Capacity DC Power Supplies Installed