Mx960 Site Preparation Checklist - Juniper MX960 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX960:
Table of Contents

Advertisement

Table 79: Router Environmental Specifications (continued)
Description
Relative humidity
Temperature
Seismic
Maximum thermal output
NOTE:
Install the router only in restricted areas, such as dedicated equipment rooms and
equipment closets, in accordance with Articles 110-16, 110-17, and 110-18 of the National
Electrical Code, ANSI/NFPA 70.
RELATED DOCUMENTATION
Tools and Parts Required to Maintain the MX960 Router | 591
Definition of Safety Warning Levels

MX960 Site Preparation Checklist

The checklist in
Table 80 on page 182
router installation.
Value
Normal operation ensured in relative humidity range of 5% to
90%, noncondensing
Normal operation ensured in temperature range of 32°F (0°C)
to 104°F (40°C)
Nonoperating storage temperature in shipping container:
–40°F (–40°C) to 158°F (70°C)
Designed to meet Telcordia Technologies Zone 4 earthquake
requirements
AC power: 27,007 BTU/hour (7920 W)
DC power: 18,987 BTU/hour (5568 W)
summarizes the tasks you must perform when preparing a site for
181

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents