Two SCBE3-MX's installed in the MX240 or MX480 are required for 1 + 1 redundancy. To provide 1 +
1 fabric redundancy, there must be an SCBE3-MX installed in slot 1.
NOTE:
If SCB 0 fails, SCB 1 will be automatically configured with four fabric planes active. In this
fail over scenario, the SCBE3-MX will support full line rate 100% redundancy.
If SCB 1 fails, SCB 0 has only two available fabric planes; therefore, in this failover mode,
the line rate will drop to 50%.
SCBE3-MX Maximum Power Consumption Per Ambient Temperature and CB slot
NOTE:
These power consumption values are for the SCBE3-MX only. They do not include
re-allocated power.
MX Model
Ambient Temperature
MX960
55°C
40°C
25C°
MX480
55°C
40°C
25C°
MX480
55°C
40°C
25C°
MX240
55°C
40°C
25C°
Maximum Power Consumption
425W
400W
385W
295W
280W
265W
425W
400W
385W
275W
260W
245W
Slot
SCB 0, SCB 1, SCB 2
SCB 0 (Master)
SCB 1 (Backup)
SCB 0 (Master)