Table 110 on page 258
specifies the holes in which you insert screws to install the mounting hardware in
an open-frame rack (an X indicates a mounting hole location). The hole distances are relative to one of the
standard U divisions on the rack. For reference, the bottom of all mounting shelves is at 0.04 in. (0.02 U)
above a U division.
Table 110: Mounting Hardware Hole Locations for Front-Mounting in an Open-Frame Rack
Hole
Distance Above U Division
30
17.26 in. (43.8 cm)
27
15.51 in. (39.4 cm)
24
13.76 in. (34.9 cm)
21
12.01 in. (30.5 cm)
18
10.26 in. (26.0 cm)
15
8.51 in. (21.6 cm)
12
6.76 in. (17.1 cm)
9
5.01 in. (12.7 cm)
6
3.26 in. (8.3 cm)
3
1.51 in. (3.8 cm)
2
0.88 in. (2.2 cm)
1
0.25 in. (0.6 cm)
To install the large mounting shelf (see
1. On the rear of each rack rail, install cage nuts, if needed, in the holes specified in
for the large shelf.
2. Partially insert a mounting screw into the highest hole specified in
3. Hange the shelf over the mounting screws using the keyhole slots located near the top of the large
shelf flanges.
Large Shelf
9.86 U
X
8.86 U
X
7.86 U
X
6.86 U
X
5.86 U
X
4.86 U
X
3.86 U
X
2.86 U
X
1.86 U
X
0.86 U
X
0.50 U
X
0.14 U
Figure 57 on page
259):
Table 110 on page
Table 110 on page 258
258.
258