Installing An Mx960 Dc Power Supply - Juniper MX960 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX960:
Table of Contents

Advertisement

Preventing Electrostatic Discharge Damage to an MX960 Router
MX960 DC Power Supply | 140
MX960 DC Power Electrical Safety Guidelines

Installing an MX960 DC Power Supply | 415

Connecting an MX960 DC Power Supply Cable | 354
Disconnecting an MX960 DC Power Supply Cable | 556
Installing an MX960 DC Power Supply
WARNING:
from the DC circuit. To ensure that all power is off, locate the circuit breaker on the
panel board that services the DC circuit, switch the circuit breaker to the off position,
and tape the switch handle of the circuit breaker in the off position.
To install a DC power supply (see
1. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that
the cable leads might become active during installation.
2. Wrap and fasten one end of the ESD grounding strap around your bare wrist, and connect the other
end of the strap to the ESD point on the chassis.
3. Move the DC circuit breaker on the power supply faceplate to the off (O) position.
4. Ensure that the release lever below the empty power supply slot is locked in the counterclockwise
position (see
Figure 151 on page
If necessary, pull the spring-loaded locking pin in the release lever away from the chassis and turn the
release lever counterclockwise until it stops. Let go of the locking pin in the release lever. Ensure that
the pin is seated inside the corresponding hole in the chassis.
5. Using both hands, slide the power supply straight into the chassis until the power supply is fully seated
in the chassis slot. The power supply faceplate should be flush with any adjacent power supply faceplates.
The small tab on the metal housing that is controlled by the release lever must be inside of the
corresponding slot at the bottom of the power supply (see
pull the power supply down in the chassis slot, prior to removing the power supply.
Before performing DC power procedures, ensure that power is removed
Figure 151 on page
418).
418):
Figure 151 on page
418). This tab is used to
549

Hide quick links:

Advertisement

Table of Contents
loading