Setting The Flying Start Function - Siemens SINAMICS V20 Operating Instructions Manual

Low voltage converters
Hide thumbs Also See for SINAMICS V20:
Table of Contents

Advertisement

5.6.3.8

Setting the flying start function

Functionality
The flying start function (enabled using P1200) allows the converter to be switched onto a
motor which is still spinning by rapidly changing the output frequency of the converter until
the actual motor speed has been found. Then, the motor runs up to setpoint using the
normal ramp time.
Flying start must be used in cases where the motor may still be turning (e.g. after a short
mains break) or can be driven by the load. Otherwise, overcurrent trips will occur.
Setting parameters
Parameter
Function
P1200
Flying start
P1202[0...2] Motor-current: flying start [%]
P1203[0...2] Search rate: flying start [%]
SINAMICS V20 Converter
Operating Instructions, 10/2019, A5E34559884-012
Setting
Settings 1 to 3 search in both directions:
= 0: Flying start disabled
= 1: Flying start always active
= 2: Flying start active after power on, fault, OFF2
= 3: Flying start active after fault, OFF2
Settings 4 to 6 search only in the direction of the setpoint:
= 4: Flying start always active
= 5: Flying start active after power on, fault, OFF2
= 6: Flying start active after fault, OFF2
This parameter defines search current used for flying start.
Range: 10 to 200 (factory default: 100)
Note: Search current settings in P1202 that are below 30% (and sometimes
other settings in P1202 and P1203) may cause motor speed to be found
prematurely or too late, which can result in F1 or F2 trips.
This parameter sets factor (in V/f mode only) by which the output frequency
changes during flying start to synchronize with turning motor.
Range: 10 to 500 (factory default: 100)
Note: A higher value produces a flatter gradient and thus a longer search
time. A lower value has the opposite effect.
Commissioning via the built-in BOP
5.6 Function commissioning
119

Hide quick links:

Advertisement

Table of Contents