Parameter list
8.2 Parameter list
Parameter
Function
P2802[0...13]
Activate FFBs
Enables free function blocks (FFB) and determines the chronological order of each function block. See P2801.
0
1
2
3
Index:
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
Dependency:
Set P2800 to 1 to enable function blocks.
All active function blocks, enabled with P2802, will be calculated in every 128 ms.
P2803[0...2]
Enable Fast FFBs
Fast free function blocks (FFB) are enabled in two steps:
1. P2803 enables the use of fast free function blocks (P2803 = 1).
2. P2801 enables each fast free function block individually and determines the chronological order
(P2801[x] = 4 to 6).
0
1
Dependency:
All active fast function blocks will be calculated in every 8 ms.
Note:
Attention: P2200 and P2803 are locked parameter against each other. PID and FFB of the same data set
cannot be active at same time.
P2810[0...1]
BI: AND 1
P2810[0], P2810[1] define inputs of AND 1 element, output is r2811.
Index:
[0]
[1]
Dependency:
P2801[0] assigns the AND element to the processing sequence.
312
Range
Factory
default
0 - 3
0
Not Active
Level 1
Level 2
Level 3
Enable timer 1
Enable timer 2
Enable timer 3
Enable timer 4
Enable ADD 1
Enable ADD 2
Enable SUB 1
Enable SUB 2
Enable MUL 1
Enable MUL 2
Enable DIV 1
Enable DIV 2
Enable CMP 1
Enable CMP 2
0 - 1
0
Disable
Enable
0 - 4294967295
0
Binector input 0 (BI 0)
Binector input 1 (BI 1)
Can be
Scaling
Data
changed
set
U, T
-
-
U, T
-
CDS
U, T
-
-
SINAMICS V20 Converter
Operating Instructions, 10/2019, A5E34559884-012
Data
Acc.
type
Level
U16
3
U16
3
U32
3