Siemens SINAMICS V20 Operating Instructions Manual page 321

Low voltage converters
Hide thumbs Also See for SINAMICS V20:
Table of Contents

Advertisement

Parameter
Function
P2851
Mode timer 1
Selects mode of timer 1. P2849, P2850, P2851 are the inputs of the timer, outputs are r2852, r2853.
0
1
2
3
10
11
12
13
Dependency:
See P2849
r2852.0
BO: Timer 1
Displays output of timer 1. P2849, P2850, P2851 are the inputs of the timer, outputs are r2852, r2853.
See r2811 for the bit field description.
Dependency:
See P2849
r2853.0
BO: Nout timer 1
Displays Not-output of timer 1. P2849, P2850, P2851 are the inputs of the timer, outputs are r2852,
r2853. See r2811 for the bit field description.
Dependency:
See P2849
P2854
BI: Timer 2
Define input signal of timer 2. P2854, P2855, P2856 are the inputs of the timer, outputs are r2857, r2858.
Dependency:
P2802[1] assigns the timer to the processing sequence.
P2855
Delay time of timer 2 [s]
Defines delay time of timer 2. P2854, P2855, P2856 are the inputs of the timer, outputs are r2857, r2858.
Dependency:
See P2854
P2856
Mode timer 2
Selects mode of timer 2. P2854, P2855, P2856 are the inputs of the timer, outputs are r2857, r2858.
See P2851 for value description.
Dependency:
See P2854
r2857.0
BO: Timer 2
Displays output of timer 2. P2854, P2855, P2856 are the inputs of the timer, outputs are r2857, r2858.
See r2811 for the bit field description.
Dependency:
See P2854
r2858.0
BO: Nout timer 2
Displays Not-output of timer 2 P2854, P2855, P2856 are the inputs of the timer, outputs are r2857, r2858.
See r2811 for the bit field description.
Dependency:
See P2854
P2859
BI: Timer 3
Define input signal of timer 3. P2859, P2860, P2861 are the inputs of the timer, outputs are r2862, r2863.
Dependency:
P2802[2] assigns the timer to the processing sequence.
P2860
Delay time of timer 3 [s]
Defines delay time of timer 3. P2859, P2860, P2861 are the inputs of the timer, outputs are r2862, r2863.
Dependency:
See P2859
SINAMICS V20 Converter
Operating Instructions, 10/2019, A5E34559884-012
Range
Factory
default
0 - 13
0
ON delay (seconds)
OFF delay (seconds)
ON/OFF delay (seconds)
Pulse generator (seconds)
ON delay (minutes)
OFF delay (minutes)
ON/OFF delay (minutes)
Pulse generator (minutes)
-
-
-
-
0 - 4294967295
0
0.0 - 9999.9
0.0
0 - 13
0
-
-
-
-
0 - 4294967295
0
0.0 - 9999.9
0.0
Can be
Scaling
Data
changed
set
U, T
-
-
-
-
-
-
-
-
U, T
-
-
U, T
-
-
U, T
-
-
-
-
-
-
-
-
U, T
-
-
U, T
-
-
Parameter list
8.2 Parameter list
Data
Acc.
type
Level
U16
3
U16
3
U16
3
U32
3
Float
3
U16
3
U16
3
U16
3
U32
3
Float
3
319