Siemens SINAMICS V20 Operating Instructions Manual page 244

Low voltage converters
Hide thumbs Also See for SINAMICS V20:
Table of Contents

Advertisement

Parameter list
8.2 Parameter list
Parameter
Function
r0968
Status word 1
Displays active status word of converter (in binary) and can be used to diagnose which commands are
active. See r0052 for the bit field description.
P0969
Resettable system run
time counter
Resettable system run time counter.
P0970
Factory reset
P0970 = 1 resets all parameters (not user defaults) to their default values.
P0970 = 21 resets all parameters and all user defaults to Factory Reset state.
When resetting all parameters by setting P0970 = 1 or P0970 = 21, please note the following aspects:
When you reset parameters through the BOP, parameters in both RAM and EEPROM are reset.
When you select USS/MODBUS communication on RS485 and the volatile storage mode (P0014[0] =
0), only parameters in RAM are reset.
When you select USS/MODBUS communication on RS485 and the non-volatile storage mode
(P0014[0] =1), parameters in both RAM and EEPROM are reset.
0
1
21
Dependency:
First set P0010 = 30 (factory settings).
Stop converter (i.e. disable all pulses) before you can reset parameters to default values.
Note:
The following parameters retain their values after a factory reset:
r0039 CO: Energy consumption meter [kWh]
P0014 Store mode
P0100 Europe/North America
P0205 Converter application
P2010 USS/MODBUS baudrate
P2011 USS address
P2021 MODBUS address
P2023 RS485 protocol selection
P8458 Clone control
When transferring P0970, the converter uses its processor to carry out internal calculations. Communica-
tions are interrupted for the time that it takes to make these calculations.
P0971
Transfer data from RAM
to EEPROM
Transfers values from RAM to EEPROM when set to 1.
Transfers new user default values from RAM to EEPROM when set to 21.
0
1
21
242
Range
Factory
default
-
-
0 - 4294967295
0
0 - 21
0
Disabled
Parameter reset
User Default Parameter Reset
0 - 21
0
Disabled
Start transfer
Start User Defaults transfer
Can be
Scaling
Data
changed
set
-
-
-
T
-
-
C(30)
-
-
U, T
-
-
Operating Instructions, 10/2019, A5E34559884-012
Data
Acc.
type
Level
U16
3
U32
3
U16
1
U16
3
SINAMICS V20 Converter

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents