Technical specifications
Firmware version
Rated voltage
Wireless technology and working frequency
Maximum radio frequency power
Wireless modulation type
Modulation technology
Antenna gain
Extreme temperature range
* EIRP means effective isotropic radiated power.
Note
Depending on environmental conditions, the maximum wireless communication distance
(without barrier) can reach 140 m.
Fitting SINAMICS V20 Smart Access to the converter
For more safety instructions during the fitting process, see Section "Fitting SINAMICS V20
Smart Access to the converter (Page 141)".
Resetting Wi-Fi configuration
When the converter is in power-on state, pressing the reset button on the module resets the
Wi-Fi configuration to defaults:
● Wi-Fi SSID: V20 smart acess_xxxxxx ("xxxxxx" stands for the last six characters of the
MAC address of SINAMICS V20 Smart Access)
● Wi-Fi password: 12345678
● Frequency channel: 1
SINAMICS V20 Converter
Operating Instructions, 10/2019, A5E34559884-012
Options and spare parts
≥ V01.04.02
24 V DC
Wi-Fi 2400 MHz to 2483.5 MHz
17.5 dBm (EIRP*)
802.11 b/g
802.11b: CCK, DSSS
802.11g: OFDM
1.9 dBi
-10 °C to 60 °C
B.1 Options
401

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6sl3210-5be24-0uv0