Introduction To Parameters; Edition - Siemens Sinamics G120 Series Parameter Manual

Hide thumbs Also See for Sinamics G120 Series:
Table of Contents

Advertisement

Parameters

Introduction to Parameters

1.1
Introduction to Parameters
The layout of the parameter description is as follows.
Fig. 1-1
Fig. 1-2
Parameter number
Indicates the relevant parameter number. The numbers used are 4-digit numbers
in the range 0000 to 9999. Only for PROFINET there are a few parameters in the
range of 61.000. Numbers prefixed with an "r" indicate that the parameter is a
"read-only" parameter, which displays a particular value but cannot be changed
directly by specifying a different value via this parameter number.
All other parameters are prefixed with a "P". The values of these parameters can
be changed directly in the range indicated by the "Min" and "Max" settings in the
header. If these values have a physical unit, it is shown in brackets.
[index] indicates that the parameter is an indexed parameter and specifies the
range of indices available.
.0...15 indicates that the parameter has several bits, which can be evaluated or
connected individually.
1-8
Read-only parameter
Write parameter
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
leseparameter.pdf
schreibparameter.pdf